KitchenAid Refrigerator Over Temperature Alarm: Reset Steps
A flashing Over Temperature light on a KitchenAid built-in fridge means it ran too warm for too long. Here is what triggers it and how to reset it.

A flashing Over Temperature light on a KitchenAid built-in refrigerator tells you the fridge or freezer ran too warm for too long at some point. The alarm starts when the refrigerator compartment climbs above 48°F (9°C), or the freezer climbs above 15°F (-9°C), for longer than 1¹⁄₂ hours. The sound stops by itself once temperatures recover, and you press the reset button to clear the light. If the light keeps blinking after that, cut power at the circuit breaker for five minutes and turn it back on.
The steps below follow KitchenAid’s help pages for built-in refrigerators, the Over Temperature Light page and the Temperature Alarm page.
What sets off the Over Temperature alarm?
Two temperature limits trigger it, one for each compartment. In the refrigerator section the limit is 48°F (9°C). In the freezer it is 15°F (-9°C). Either compartment has to stay above its limit for longer than 1¹⁄₂ hours before the alarm sounds, so a door left open briefly will not usually set it off.
KitchenAid gives a power outage as one example of an over-temperature event. When the power returns and the compartments cool down, the audible alarm shuts off on its own.
Why does the light keep flashing after the alarm goes quiet?
The light is a record that the event happened. The sound stops when the temperature is back to normal, but the indicator keeps flashing so you know the refrigerator or freezer was too warm while you were away or asleep. KitchenAid’s Temperature Alarm page says the light continues until you press the Alarm control. The Over Temperature Light page names the control “Over Temperature Reset”. The label depends on the page and, presumably, the control panel, so look for whichever of the two appears on yours.
Once the light is cleared, check what the temperature was doing. If the compartments are cold again, the alarm did its job. If food in the fridge or freezer felt warm or began to thaw during the event, treat that as a separate question about the food and the cause of the warming.
Why does a newly installed refrigerator sound the alarm?
A refrigerator that has just been turned on starts out warm. KitchenAid says the alarm and indicator light will activate every 1¹⁄₂ hours until the refrigerator drops below 48°F (9°C) and the freezer drops below 15°F (-9°C). During that first cooldown the alarm is expected.
To silence the alarm and the light while the unit is still cooling, press the “Over Temperature Reset” button. The alarm will come back at the next 1¹⁄₂ hour mark if either compartment is still above its limit, and it stops coming back once both have reached their targets. If you are setting the dial yourself, our guide to adjusting fridge temperature and reading the dial numbers explains the settings.
How do I reset the power to clear a blinking light?
If the Over Temperature Reset light is blinking or flashing, KitchenAid suggests resetting power to the refrigerator at the breaker box. Built-in models are usually wired to a dedicated circuit, and the page speaks of “circuit breaker(s)”, so find every breaker that feeds the unit.
- Turn off the circuit breaker or breakers for the refrigerator and leave them off for five minutes.
- Turn the breaker or breakers back on.
- Watch the refrigerator for a couple of minutes to confirm the error does not come back.
- Check that the refrigerator is running normally.
The page does not say how long to wait after the final step, only that you should watch it for a couple of minutes first.
What if the temperature does not return to normal?
Then the problem is cooling, not the alarm. KitchenAid points readers of the Temperature Alarm page to the “Temperature Concerns” section of its troubleshooting guide. The Over Temperature Light page sends you to a “Not Cooling Properly” section instead. Both pages treat a warm compartment as the thing to fix and the alarm as the signal.
Ice and frost can also get in the way of cooling. A blocked defrost drain is one cause of water and ice problems, and our article on cleaning a refrigerator defrost drain lists the signs of a clog and the cleaning steps. KitchenAid’s pages do not connect the alarm to a clogged drain, so use that guide only if you also see the symptoms it describes.
When should I contact KitchenAid or book service?
If the reset does not clear the light, or the light comes back and the temperatures are still high, KitchenAid’s pages direct you to contact the company or schedule service. They give separate links for the United States and Canada, and the scheduling option uses a list of preferred service providers. Have the model number ready when you call or book.
Quick answers
What is the Over Temperature limit for the fridge section?
KitchenAid sets it at 48°F (9°C). The freezer limit is 15°F (-9°C). Either one must be exceeded for longer than 1¹⁄₂ hours.
Will the alarm turn itself off?
The sound will, once temperatures return to normal. The indicator light keeps flashing until you press the reset or alarm button.
How long should the breaker stay off?
KitchenAid says five minutes, then switch it back on and watch the refrigerator for a couple of minutes.
Does the alarm sound every time I open the door?
The pages describe the alarm only as a response to temperatures staying above the limits for longer than 1¹⁄₂ hours, or to a new installation still cooling down.
Checked against official sources in November 2026. Hours, prices and rules change: confirm on the official page before you go or apply.